Subskrybuj RSS RSS
envelope  |  site map  | 
pl
Search on Website

Communication Drivers Included in the Price

 

COMMUNICATION DRIVERS INCLUDED IN THE PRICE

Driver

Protocol

Use

ADAM

ADAM 4000

RS485 serial bus protocol for ADAM 4000 series modules.

AdvWise

HTTP/REST

Used to exchange data between the Asix.Evo system and the WISE series modules manufactured by Advantech. The communication is carried out using an Ethernet link using the HTTP / REST protocol.

Aggregate

 -

Driver allows definition of variables the values of which are generated as a result of calculations performed on other variables of the Asix.Evo system.

AirPointer

HTTP

The AirPointer is used for data exchange between Asix.Evo and air monitoring station AirPointer developed by Recordum Messtechnik GmbH, Austria. The transmission is performed with use of HTTP protocol using info.php and download.php websites of monitoring station web server.

AK

AK

Protocol for data exchange between Asix.Evo system and Emerson MLT2 analyzers.

AM_SA85

MODBUS PLUS

MODBUS PLUS network protocol, based on Schneider Electric AM-SA85-000 card.

AREVA

AREVA

Protocol for digital protection devices MiCOM of AREVA; the list of serviced devices includes MiCOM P127 and MiCOM P34x series.

AS511

AS511

Protocol using programming device interface of SIMATIC S5 PLC. 

AS512

AS512

Protocol of CP524/525/544 communication processors.

AS512S7

AS512

AS512 protocol for SIMATIC S7 PLC's, based on CP340 processor.

BACnetIP

BACnet/IP

Protocol for data exchange with devices with BACnet/ IP protocol interface. The driver does not support all BACnet standard objects (details in driver user's documentation).

Baski

BASKI

Protocol for data exchange between Asix.Evo system and BASKI system.

BAZA

-

Communication protocol which allows to import database into  Asix.Evo system. Access to database is realized based on ADO technology.

BUFOR

BUFOR

Communication protocol using memory buffer; data exchange with driver developed by user.

Calec

CALEC MCP

Communication with CALEC MCP devices by Aquametro.

CAN_AC_PCI

CANBUS

Protocol of CAN network based on CAN_AC1_PCI and CAN_AC2_PCI cards of Softing GmbH.

CAN_OPEN

CANBUS

CANBUS network protocol based on PCI_712 NT card by SELECTRON LYSS AG.

Cip

CIP

Used to exchange data between the Asix.Evo system and the Danfoss VLT MCA 121 EtherNet / IP modules using the CIP protocol in the Unconnected Messages (UCMM) mode.  

CipAB

EtherNet/IP

Data exchange between Asix.Evo and PLCs of Logix5000 by Allen-Bradley.

CipOmron

EtherNet/IP

Used to exchange data between the Asix.Evo system and Omron NJ / NX series drivers using the EtherNet / IP protocol in Explicit Messaging mode.

COMLI

COMLI

COMmunication LInk protocol allowing communication with AC800C, AC800M and AC250 PLCs from ABB as well as SattCon PLC. Data exchange takes place over RS-232 or RS-485 serial link.

CPIII

CPIII

Communication protocol for  CP-III/E control panels used to control compressors  manufactured by MYCOM (MAYEKAWA).

CZAZ

CZAZ

Protocol for digital protection devices CZAZ-U and CZAZ-UM of ZEG-Energetyka.

DataPAF

DataPAF

Communication protocol for energy meters DataPAF.

DDE

DDE KLIENT

DDE protocol of WINDOWS XP (and later) system, communication with any PLC using its DDE server.

Diris

Ethernet in Open Modbus TcpIp mode

Used to exchange data between the Asix.Evo system and Diris Digiware modules using the Diris D-50 gateway. Data exchange takes place via the Ethernet link in the Open Modbus TcpIp mode.

Diva

DIVA

Protocol for control of industrial DIVA cameras manufactured by VDG Security B.V.

Dlms

DLMS

Protocol to exchange data with electricity meters from ZxD/ZxG/ZxQ family by Landys &Gyr.

DlmsTcpip

DLMS

Used for data echange between the Asix.Evo system and electric energy counters of Landys & Gyr company, using the DLMS protocol. The communication is performed through Ethernet.

DMS285

DMS285

Serial bus protocol for DURAG D-MS 285 pollution emission  analyzers.

DMS500

DMS500

Serial bus protocol for DURAG D-MS 500 pollution emission  analyzers.

DNP3

DNP3

Driver of Distributed Network Protocol Version 3 for Electrical Power Engineering Control and Supervision Systems.

DP

PROFIBUS DP

PROFIBUS DP network protocol, based on PROFIboard card by Softing GmbH.

DP5412

PROFIBUS DP

PROFIBUS DP network protocol, based on CP5412 (A2) or CP5613.

DSC

DSC

DSC PLC protocol (analysers for chlorine ion content in water).

DXF351

DXF351

Communication protocol for Compart DXF351 devices by Endress+Hauser.

E2TangoTcpip

Manufacturer’s protocol

Communication protocol of e2TANGO device by Elektrometal Energetyka.

Ecl

Modbus TCP

Protocol for Communication with ECL Comfort 210/310 controllers made By Danfoss.

EcoMUZ 

EcoMUZ

Protocol used for data exchange between Asix.Evo and Microprocessor Protecting ecoMUZ devices made by JM Tronik.

ecoMuz2

EcoMUZ

Protool used for data exchange between Asix.Evo and Microprocessor Protecting ecoMUZ-2 devices made by JM Tronik.

EQABP

PN-EN-62056-21

Protocol used to exchange data with  EQABP electricity meters of Pozyton through RS-485 interface.

EQM

PN-EN-62056-21

Protocol used to exchange data with  EQM electricity meters of Pozyton through RS-485 interface.

Esser

Esser

Protocol fo data exchange with Esser 8008 fire protection by Honeywell.

FESTO

FESTO Command Interpreter

Serial bus protocol for FESTO PLC's, using diagnostic interface.

FILE2ASIX

FILE2ASIX

Communication protocol used for importing data from the text files of the specified structure  into  Asix.Evo system.

FP1001

FP1001

Serial bus protocol for heat and steam flow meters by METRONIC Kraków.

Gci

Manufacturer’s protocol

Used to exchange data between the Asix.Evo system and the E94AYCEN communication module from Lenze Drive Systems GmbH. Data exchange takes place via an Ethernet link using the manufacturer protocol called GCI.

GFCAN

CANBUS

CANBUS network protocol based on CanCard by Garz&Fricke Industrieautomation GmbH.

Global

-

Driver used to exchange data between  Asix.Evo application and so-called exchange file, which is a container for the current parameters of the driver variable (name, status, value, timestamp).

IEC61850

IEC61850

Power stations protocol. Requires purchase of INFO-TECH 61850 CCC library.

COMPOWAY/F

K3N

Meters protocol of K3N series by OMRON.

K-Bus

K-Bus

Communication protocol implemented within DECAMATIC regulators of VIESSMAN boilers.

KMP

Kamstrup Meter Protocol (KMP)

Used to exchange data between the Asix.Evo system and the Kamstrup Multical 801 meters according to the Kamstrup Meter Protocol (KMP). Data exchange takes place via RS-232. A cable manufactured by Kamstrup symbol 66-99-106 is required for connection to the meter.

Lb480

Manufacturer’s protocol

Used to read the current and historical data from the concentrator LB-480 manufactured by LAB_EL Elektronika Laboratoryjna.

LG

LG proprietary protocol

Serial communication via dedicated protocol with Master-K and Glofa GM PLCs.

Logo 

LOGO

Used to exchange data between  Asix.Evo system and Logo OBA5 controller from SIEMENS with use of programmer interface of the controller.

LUMBUS

LUMBUS

Communication protocol for meters manufactured by LUMEL.

Lzqm

PN-EN-62056-21

Protocol for exchange of data with LZQM electricity meters, produced by POZYTON Electronic Measuring Instruments Facility in Częstochowa.

M200

M200

Communication protocol for data exchange between  Asix.Evo and M210G Spirax Sarco stations.

MACMAT

GAZ_MODEM

Serial bus protocol for gas flow correctors MACMAT and COMMON.

Max1000

MAX-1000

Protocol to exchange data with MAX 1000 camera managing system of ULTRAK.

M-BUS

M-BUS

Serial bus protocol according to EN 1434-3, frequently implemented within heat meters (eq. MULTICAL by KAMSTRUP). Data exchange over RS-232 serial links, (attention: third-party master station of M-Bus network required).

MEC

MEC

Proprietary protocol allowing communication with heat meters MEC07 and MEC08 manufactured by ITC Łódź.

MegaMuz

Modbus

Protocol for communication with microprocessor security devices  of MegaMuz type by JM-Tronik.

MegaMuz2

Modbus

Used to exchange data between the Asix.Evo system and microprocessor protection devices of MegaMuz2 type developed by JM-Tronik, Warsaw. Communication is carried out in MODBUS RTU mode via serial link. 

MegaMuz_TCPIP

Modbus TCP

Protocol for communication by Ethernet with microprocessor security devices of MegaMuz type by JM-Tronik.

MegaMuz2_TCPIP

Modbus TCP

Used to exchange data between the Asix.Evo system and microprocessor protection devices of MegaMuz2 type developed by JM-Tronik, Warsaw. Communication is carried out in MODBUS RTU mode on TCPIP via Ethernet.

MELSECA

A1SJ71C24-R2

Protocol of series link for MELSEC-A and FX2n PLCs, format 1 dedicated.

MelsecTcpip

Melsec

Used to exchange data between the Asix.Evo system and Mitsubishi controllers according to the Melsec Communication Protocol. Data exchange takes place via an Ethernet connection.

MEVAS

MEVAS

Serial bus protocol for MEVAS pollution emission analyzers.

MicroSmart   

MicroSmart

Used for exchanging data with MicroSmart controllers of IDEC.

MODBUS

MODBUS RTU

Modbus RTU protocol for communication with devices for measurement and registration of electrical values in 1-, 2- and 3-phase nets of low and high voltage – DIRIS A10, A20, A40/A41 of SOCOMEC.

MODBUS_TCP/IP

MODBUS TCP

MODBUS network protocol based on TCP/IP, according  to OPEN MODBUS/TCP specification by Schneider Electric.

MODBUS_TCPIP_Slave

MODBUS TCP

For data exchange between the Asix.Evo system and other computers/devices with use of the MODBUS protocol realized via an Ethernet network with the TCP/IP protocol.

MODBUSSLV

MODBUS SLAVE

MODBUS protocol,  Asix.Evo in SLAVE mode.

MPI

MPI (converter)

Protocol of MPI network for SIMATIC S7 PLC's, based on PC/MPI converter.

MPS

MPS

Serial bus protocol for MPS power network parameter meters MPS by OBR Metrologii Elektrycznej in Zielona Góra.

Mqtt

MQTT

Used to exchange data between the Asix.Evo system and the MQTT protocol brokers. Version 3.1.1 of the MQTT protocol is supported.

MSP1X

MSP1X

Serial bus protocol for MSP-1x PLC's by ELMONTEX.

Mt723

MQTT

Used to collect data sent to Asix.Evo from MT-723 recorders manufactured by Inventia. Data exchange takes place via Ethernet using the MtLib5 library developed by Inventia.

Muel

MUEL

Protocol to exchange data between  Asix.Evo and a MUEL system maintenance computer.

MultiMuz

Modbus

RS232/485 serial link protocol for microprocessor devices of MultiMUZ type (manufactured by JM-Tronik)

MultiMuz_TCPIP

MODBUS TCP

Protocol for data exchange with microprocessor devices of  MultiMUZ type (manufactured by JM-Tronik) over Ethernet by means of TCP or UDP.

MultiMuz3

Modbus

RS232/485 serial link protocol of microprocessor security devices MultiMUZ3 type, produced by JM-Tronik.

MultiMuz3_tcpip

MODBUS TCP

Protocol for data exchange with microprocessor devices of MultiMUZ3 type (manufactured by JM-Tronik). Communication realized in MODBUS RTU mode on TCPIP with the use of Ethernet and 10502 port.

MUPASZ

Modbus

Serial bus protocol for universal microprocessor MUPASZ PLC for power industry protection devices - Institute of Telecommunication and Radio Engineering in Warsaw.

Mupasz710_RS

Modbus

Protocol for data exchange with microprocessor devices of  MUPASZ 710 type made by Institute of Telecommunication and Radio Engineering in Warsaw.

MupaszRtu

Modbus

Protocol for data exchange between  Asix.Evo and Mupasz2001G, Mupasz07, Mupasz Compact G01 devices, produced by ITR Warszawa. Communication is performed via serial links in RS485 standard.

MupaszRtu_TCPIP

MODBUS TCP

Protocol for data exchange with microprocessor protecting devices of MUPASZ 710 type, made by Institute of Telecommunication and Radio Engineering in Warsaw. The communication is performed in MODBUS RTU mode via Ethernet link, using port no. 502.

Mus04   

MUS

Protocol  to exchange data with microprocessor-based control devices MUS-04 manufactured by ELEKTROMETAL S.A. from Cieszyn.

MUZ

MUZ

Protocol of MUZ microprocessor PLC for power industry protection devices.

NCP

MN_Invensys

Protocol  to exchange data with  MN-series controllers from Invensys (former Satchwell).

NetLink

PROFIBUS / MPI

S7 protocol of PROFIBUS network using NetLink Lite module of SYSTEME HELMHOLZ.

NetLinkPro

PROFIBUS / MPI

Protocol for exchanging data with S7 PLCs with use of NETLink PRO (gateway Ethernet <-> MPI/Profibus) manufactured by SYSTEME HELMHOLZ.

None

-

The None  protocol doesn’t realize a physical connection with the controller. It may be used for:

• application testing in simulation mode,

• data exchange between  Asix.Evo applications by means of process variables.

NordicRF

NordicID protocol

Protocol  to exchange data with Nordic ID RF 601 bar code reader of NordicID.

OMRON

HOSTLINK

Serial bus protocol for SYSMAC series PLCs.

OmronTcpip

FINS

Protocol for data exchange with Omron controllers supporting the FINS/UDP and FINS/TCP protocols.

OPC

OPC KLIENT

OPC (OLE for Process Control) protocol, communication with any PLC using its OPC server, according to OPC 2.04 specification.

OPCUA

OPC UA CLIENT

OPC UA protocol, communication with any PLC according to OPC UA specification.

OpcLogger

 

Used to register measurement series read from current data OPC servers.

Pa5

Pa5

Communication protocol for data exchange between  Asix.Evo and PA-5 converters of POWOGAZ S.A. Poznan.

PD21

LUMBUS

Protocol for data exchange with PD21 concentrator made by LUMEL S.A.

Pmc4000

PMC-4000

Communication protocol  for data exchange between   Asix.Evo and  POLON 4800 fire alarm control panel; data are transferred via serial interface RS-232.

PPI

PPI

Protocol of PPI interface for SIMATIC S7 series 200 PLC's, based on PC/PPI converter.

Protherm300

PROTHERM

Protocol of  Protherm 300 DIFF PLC of Process-Electronic GmbH (RS-422 serial link).

PROTRONICPS

PROTRONICPS

Communication protocol for PROTRONIC PS regulators by Hartmann & Braun.

REST

HTTP/HTTPS

Used to exchange data between the Asix.Evo system application and the REST server.

S700

AK

Protocol for gas analyzers by MAIHAK.

S7Opt

 

Used to exchange data with the SIMATIC S7-1500 and S7-1200 series controllers (from version 4.0), constituting a completely new generation of Siemens controllers.

S7_TCPIP

S7_Ethernet

Used for data exchange with SIMATIC S7 PLC’s through Ethernet connection with use of standard computer network card; the product does not require the installation of SIEMENS SIMATIC NET software on  Asix.Evo system PC as well as the adaptation of PLC software for data exchange purposes.

SAPIS7

MPI (CP5611/SOFTNET)

Protocol of MPI network for SIMATIC S7 PLC's , based on CP5611/SOFTNET.

SAPIS7

PROFIBUS

S7 protocol of PROFIBUS network based on CP5412 (A2) or CP5613.

S-BUS

S-Bus

Protocol of programmer unit interface and S-Bus  network for SAIA  Burgess Electronics PLCs.

SbusTcpip

Ethernet S-Bus

Protocol used for data exchange between  Asix.Evo system and PLCs of PCD SAIA-Burgess family by means of TCP/IP.

Simulator

 

Used to generate test trends. The trends generated can be based on previously created csv files, or calculated by the driver as a random trends and a sinusoidal trend.

SINECH1

SINEC H1

Protocol of Ethernet industry network for SIMATIC S5 PLC's, SEND/RECEIVE interface, based on CP1413.

SINECL2

SINEC L2

Protocol of PROFIBUS network with SEND/RECEIVE (FDL) interface for SIMATIC S5.

Si400

SINTONY SI

Communication protocol  for alarm exchanges with Sintony SI 400 of SIEMENS.

SNG

SNG-Synergia/IP

Protocol for data exchange between  Asix.Evo and SNG systems provided by the Warsaw based Synergia Tech company, via an Ethernet link.

SNMP

SNMPv1 i SNMPv2c

SNMPv1 and SNMPv2c protocols – management of various elements of telecommunication networks, such as routers, switches, computers, or telephone switchboards. The driver performs its functions by using the SNMP Management API.

SNPX

SNPX

Protocol for communication with GE_FANUC 90-30 PLCs as well as GE_FANUC 90 CMM and PCM modules.

Sp100H

Manufacturer’s protocol

Protocol for exchanging data between  Asix.Evo and SP-100H controller of storm water center Aqua Center Industrial 100 H 14-60, produced by MARLEY Polska Sp. z o.o. The transmission is performed via serial links using RS-232 std serial port.

SPA

SPA

SPA bus protocol for protection of switching stations manufactured by ABB.

Srio

ANSI X3.28

Protocol for data exchange with  SRIO 500M ABB hub; communication via RS-232 interface; the transport layer  based on ANSI X3.28 protocol in full-duplex mode with BCC checksum.

SRTP

SRTP

SRTP protocol allowing communication over TCP/IP with VersaMax Nano/Micro PLC’s ( based on IC200SET001 converter ) and VersaMax or Series 90 PLC's over TCP/IP ( based on IC 693 CMM321).

TALAS

TALAS

Serial bus protocol for TALAS pollution emission analyzers according to the TALAS 2.3 (007)22 specification.

TwinCAT

(with use of Beckhoff libraries)

Data exchange between  Asix.Evo and PLCs of Beckhoff Industrie Elektronik: CX1000, TwinCAT PLC ( PC based control system), BC9000, BX9000. Communication is based on Ethernet.

TwinCATTcpip

ADS/AMS over TCPIP (without use of Beckhoff libraries)

Data exchange between  Asix.Evo and PLCs of Beckhoff Industrie Elektronik:  CX1000, TwinCAT PLC ( PC based control system), BC9000, BX9000.  Communication is based on Ethernet with the use of ADS interface.

Vantage

Manufacturer’s protocol

Readout of current data from weather stations of Vantage Pro family developed by Davis Instruments Corp., USA.

Wago

Wago

Protocol for data exchange with Wago PLCs.  Communication realized with the use of Ethernet in UDP mode based on network variable list ("Network Variables”).

WagoUps

Wago

Used to communicate the Asix.Evo system with WAGO 787-87x power supplies using the RS-232 or Ethernet serial link.

ZdarzenieZmienna

-

The driver is used to generate process variables of WORD

types (16-bit word) on the basis of current values of alarm events in the  Asix.Evo system.

ZxD400

IEC 61107

ZxD400 driver is used for data exchange between  Asix.Evo and electric energy counters of ZxD400 type, manufactured by Landys & Gyr, via RS-485 interface.