COMMUNICATION DRIVERS INCLUDED IN THE PACKAGE |
||
Driver |
Protocol |
Use |
ADAM |
ADAM 4000 |
RS485 serial bus protocol for ADAM 4000 series modules. |
AdvWise |
HTTP/REST |
Used to exchange data between the Asix.Evo system and the WISE series modules manufactured by Advantech. The communication is carried out using an Ethernet link using the HTTP / REST protocol. |
Aggregate |
- |
Driver allows definition of variables the values of which are generated as a result of calculations performed on other variables of the Asix.Evo system. |
AirPointer |
HTTP |
The AirPointer is used for data exchange between Asix.Evo and air monitoring station AirPointer developed by Recordum Messtechnik GmbH, Austria. The transmission is performed with use of HTTP protocol using info.php and download.php websites of monitoring station web server. |
AK |
AK |
Protocol for data exchange between Asix.Evo system and Emerson MLT2 analyzers. |
AM_SA85 |
MODBUS PLUS |
MODBUS PLUS network protocol, based on Schneider Electric AM-SA85-000 card. |
AREVA |
AREVA |
Protocol for digital protection devices MiCOM of AREVA; the list of serviced devices includes MiCOM P127 and MiCOM P34x series. |
AS511 |
AS511 |
Protocol using programming device interface of SIMATIC S5 PLC. |
AS512 |
AS512 |
Protocol of CP524/525/544 communication processors. |
AS512S7 |
AS512 |
AS512 protocol for SIMATIC S7 PLC's, based on CP340 processor. |
BACnetIP |
BACnet/IP |
Protocol for data exchange with devices with BACnet/ IP protocol interface. The driver does not support all BACnet standard objects (details in driver user's documentation). |
Baski |
BASKI |
Protocol for data exchange between Asix.Evo system and BASKI system. |
BAZA |
- |
Communication protocol which allows to import database into Asix.Evo system. Access to database is realized based on ADO technology. |
BUFOR |
BUFOR |
Communication protocol using memory buffer; data exchange with driver developed by user. |
Calec |
CALEC MCP |
Communication with CALEC MCP devices by Aquametro. |
CAN_AC_PCI |
CANBUS |
Protocol of CAN network based on CAN_AC1_PCI and CAN_AC2_PCI cards of Softing GmbH. |
CAN_OPEN |
CANBUS |
CANBUS network protocol based on PCI_712 NT card by SELECTRON LYSS AG. |
Cip |
CIP |
Used to exchange data between the Asix.Evo system and the Danfoss VLT MCA 121 EtherNet / IP modules using the CIP protocol in the Unconnected Messages (UCMM) mode. |
CipAB |
EtherNet/IP |
Data exchange between Asix.Evo and PLCs of Logix5000 by Allen-Bradley. |
CipOmron |
EtherNet/IP |
Used to exchange data between the Asix.Evo system and Omron NJ / NX series drivers using the EtherNet / IP protocol in Explicit Messaging mode. |
COMLI |
COMLI |
COMmunication LInk protocol allowing communication with AC800C, AC800M and AC250 PLCs from ABB as well as SattCon PLC. Data exchange takes place over RS-232 or RS-485 serial link. |
CPIII |
CPIII |
Communication protocol for CP-III/E control panels used to control compressors manufactured by MYCOM (MAYEKAWA). |
CZAZ |
CZAZ |
Protocol for digital protection devices CZAZ-U and CZAZ-UM of ZEG-Energetyka. |
DataPAF |
DataPAF |
Communication protocol for energy meters DataPAF. |
DDE |
DDE KLIENT |
DDE protocol of WINDOWS XP (and later) system, communication with any PLC using its DDE server. |
Diris |
Ethernet in Open Modbus TcpIp mode |
Used to exchange data between the Asix.Evo system and Diris Digiware modules using the Diris D-50 gateway. Data exchange takes place via the Ethernet link in the Open Modbus TcpIp mode. |
Diva |
DIVA |
Protocol for control of industrial DIVA cameras manufactured by VDG Security B.V. |
Dlms |
DLMS |
Protocol to exchange data with electricity meters from ZxD/ZxG/ZxQ family by Landys &Gyr. |
DlmsTcpip |
DLMS |
Used for data echange between the Asix.Evo system and electric energy counters of Landys & Gyr company, using the DLMS protocol. The communication is performed through Ethernet. |
DMS285 |
DMS285 |
Serial bus protocol for DURAG D-MS 285 pollution emission analyzers. |
DMS500 |
DMS500 |
Serial bus protocol for DURAG D-MS 500 pollution emission analyzers. |
DNP3 |
DNP3 |
Driver of Distributed Network Protocol Version 3 for Electrical Power Engineering Control and Supervision Systems. |
DP |
PROFIBUS DP |
PROFIBUS DP network protocol, based on PROFIboard card by Softing GmbH. |
DP5412 |
PROFIBUS DP |
PROFIBUS DP network protocol, based on CP5412 (A2) or CP5613. |
DSC |
DSC |
DSC PLC protocol (analysers for chlorine ion content in water). |
DXF351 |
DXF351 |
Communication protocol for Compart DXF351 devices by Endress+Hauser. |
E2TangoTcpip |
Manufacturer’s protocol |
Communication protocol of e2TANGO device by Elektrometal Energetyka. |
Ecl |
Modbus TCP |
Protocol for Communication with ECL Comfort 210/310 controllers made By Danfoss. |
EcoMUZ |
EcoMUZ |
Protocol used for data exchange between Asix.Evo and Microprocessor Protecting ecoMUZ devices made by JM Tronik. |
ecoMuz2 |
EcoMUZ |
Protool used for data exchange between Asix.Evo and Microprocessor Protecting ecoMUZ-2 devices made by JM Tronik. |
EQABP |
PN-EN-62056-21 |
Protocol used to exchange data with EQABP electricity meters of Pozyton through RS-485 interface. |
EQM |
PN-EN-62056-21 |
Protocol used to exchange data with EQM electricity meters of Pozyton through RS-485 interface. |
Esser |
Esser |
Protocol fo data exchange with Esser 8008 fire protection by Honeywell. |
FESTO |
FESTO Command Interpreter |
Serial bus protocol for FESTO PLC's, using diagnostic interface. |
FILE2ASIX |
FILE2ASIX |
Communication protocol used for importing data from the text files of the specified structure into Asix.Evo system. |
FP1001 |
FP1001 |
Serial bus protocol for heat and steam flow meters by METRONIC Kraków. |
Gci |
Manufacturer’s protocol |
Used to exchange data between the Asix.Evo system and the E94AYCEN communication module from Lenze Drive Systems GmbH. Data exchange takes place via an Ethernet link using the manufacturer protocol called GCI. |
GFCAN |
CANBUS |
CANBUS network protocol based on CanCard by Garz&Fricke Industrieautomation GmbH. |
Global |
- |
Driver used to exchange data between Asix.Evo application and so-called exchange file, which is a container for the current parameters of the driver variable (name, status, value, timestamp). |
IEC61850 |
IEC61850 |
Power stations protocol. Requires purchase of INFO-TECH 61850 CCC library. |
COMPOWAY/F |
K3N |
Meters protocol of K3N series by OMRON. |
K-Bus |
K-Bus |
Communication protocol implemented within DECAMATIC regulators of VIESSMAN boilers. |
KMP |
Kamstrup Meter Protocol (KMP) |
Used to exchange data between the Asix.Evo system and the Kamstrup Multical 801 meters according to the Kamstrup Meter Protocol (KMP). Data exchange takes place via RS-232. A cable manufactured by Kamstrup symbol 66-99-106 is required for connection to the meter. |
Lb480 |
Manufacturer’s protocol |
Used to read the current and historical data from the concentrator LB-480 manufactured by LAB_EL Elektronika Laboratoryjna. |
LG |
LG proprietary protocol |
Serial communication via dedicated protocol with Master-K and Glofa GM PLCs. |
Logo |
LOGO |
Used to exchange data between Asix.Evo system and Logo OBA5 controller from SIEMENS with use of programmer interface of the controller. |
LUMBUS |
LUMBUS |
Communication protocol for meters manufactured by LUMEL. |
Lzqm |
PN-EN-62056-21 |
Protocol for exchange of data with LZQM electricity meters, produced by POZYTON Electronic Measuring Instruments Facility in Częstochowa. |
M200 |
M200 |
Communication protocol for data exchange between Asix.Evo and M210G Spirax Sarco stations. |
MACMAT |
GAZ_MODEM |
Serial bus protocol for gas flow correctors MACMAT and COMMON. |
Max1000 |
MAX-1000 |
Protocol to exchange data with MAX 1000 camera managing system of ULTRAK. |
M-BUS |
M-BUS |
Serial bus protocol according to EN 1434-3, frequently implemented within heat meters (eq. MULTICAL by KAMSTRUP). Data exchange over RS-232 serial links, (attention: third-party master station of M-Bus network required). |
MEC |
MEC |
Proprietary protocol allowing communication with heat meters MEC07 and MEC08 manufactured by ITC Łódź. |
MegaMuz |
Modbus |
Protocol for communication with microprocessor security devices of MegaMuz type by JM-Tronik. |
MegaMuz2 |
Modbus |
Used to exchange data between the Asix.Evo system and microprocessor protection devices of MegaMuz2 type developed by JM-Tronik, Warsaw. Communication is carried out in MODBUS RTU mode via serial link. |
MegaMuz_TCPIP |
Modbus TCP |
Protocol for communication by Ethernet with microprocessor security devices of MegaMuz type by JM-Tronik. |
MegaMuz2_TCPIP |
Modbus TCP |
Used to exchange data between the Asix.Evo system and microprocessor protection devices of MegaMuz2 type developed by JM-Tronik, Warsaw. Communication is carried out in MODBUS RTU mode on TCPIP via Ethernet. |
MELSECA |
A1SJ71C24-R2 |
Protocol of series link for MELSEC-A and FX2n PLCs, format 1 dedicated. |
MelsecTcpip |
Melsec |
Used to exchange data between the Asix.Evo system and Mitsubishi controllers according to the Melsec Communication Protocol. Data exchange takes place via an Ethernet connection. |
MEVAS |
MEVAS |
Serial bus protocol for MEVAS pollution emission analyzers. |
MicroSmart |
MicroSmart |
Used for exchanging data with MicroSmart controllers of IDEC. |
MODBUS |
MODBUS RTU |
Modbus RTU protocol for communication with devices for measurement and registration of electrical values in 1-, 2- and 3-phase nets of low and high voltage – DIRIS A10, A20, A40/A41 of SOCOMEC. |
MODBUS_TCP/IP |
MODBUS TCP |
MODBUS network protocol based on TCP/IP, according to OPEN MODBUS/TCP specification by Schneider Electric. |
MODBUS_TCPIP_Slave |
MODBUS TCP |
For data exchange between the Asix.Evo system and other computers/devices with use of the MODBUS protocol realized via an Ethernet network with the TCP/IP protocol. |
MODBUSSLV |
MODBUS SLAVE |
MODBUS protocol, Asix.Evo in SLAVE mode. |
MPI |
MPI (converter) |
Protocol of MPI network for SIMATIC S7 PLC's, based on PC/MPI converter. |
MPS |
MPS |
Serial bus protocol for MPS power network parameter meters MPS by OBR Metrologii Elektrycznej in Zielona Góra. |
Mqtt |
MQTT |
Used to exchange data between the Asix.Evo system and the MQTT protocol brokers. Version 3.1.1 of the MQTT protocol is supported. |
MSP1X |
MSP1X |
Serial bus protocol for MSP-1x PLC's by ELMONTEX. |
Mt723 |
MQTT |
Used to collect data sent to Asix.Evo from MT-723 recorders manufactured by Inventia. Data exchange takes place via Ethernet using the MtLib5 library developed by Inventia. |
Muel |
MUEL |
Protocol to exchange data between Asix.Evo and a MUEL system maintenance computer. |
MultiMuz |
Modbus |
RS232/485 serial link protocol for microprocessor devices of MultiMUZ type (manufactured by JM-Tronik) |
MultiMuz_TCPIP |
MODBUS TCP |
Protocol for data exchange with microprocessor devices of MultiMUZ type (manufactured by JM-Tronik) over Ethernet by means of TCP or UDP. |
MultiMuz3 |
Modbus |
RS232/485 serial link protocol of microprocessor security devices MultiMUZ3 type, produced by JM-Tronik. |
MultiMuz3_tcpip |
MODBUS TCP |
Protocol for data exchange with microprocessor devices of MultiMUZ3 type (manufactured by JM-Tronik). Communication realized in MODBUS RTU mode on TCPIP with the use of Ethernet and 10502 port. |
MUPASZ |
Modbus |
Serial bus protocol for universal microprocessor MUPASZ PLC for power industry protection devices - Institute of Telecommunication and Radio Engineering in Warsaw. |
Mupasz710_RS |
Modbus |
Protocol for data exchange with microprocessor devices of MUPASZ 710 type made by Institute of Telecommunication and Radio Engineering in Warsaw. |
MupaszRtu |
Modbus |
Protocol for data exchange between Asix.Evo and Mupasz2001G, Mupasz07, Mupasz Compact G01 devices, produced by ITR Warszawa. Communication is performed via serial links in RS485 standard. |
MupaszRtu_TCPIP |
MODBUS TCP |
Protocol for data exchange with microprocessor protecting devices of MUPASZ 710 type, made by Institute of Telecommunication and Radio Engineering in Warsaw. The communication is performed in MODBUS RTU mode via Ethernet link, using port no. 502. |
Mus04 |
MUS |
Protocol to exchange data with microprocessor-based control devices MUS-04 manufactured by ELEKTROMETAL S.A. from Cieszyn. |
MUZ |
MUZ |
Protocol of MUZ microprocessor PLC for power industry protection devices. |
NCP |
MN_Invensys |
Protocol to exchange data with MN-series controllers from Invensys (former Satchwell). |
NetLink |
PROFIBUS / MPI |
S7 protocol of PROFIBUS network using NetLink Lite module of SYSTEME HELMHOLZ. |
NetLinkPro |
PROFIBUS / MPI |
Protocol for exchanging data with S7 PLCs with use of NETLink PRO (gateway Ethernet <-> MPI/Profibus) manufactured by SYSTEME HELMHOLZ. |
None |
- |
The None protocol doesn’t realize a physical connection with the controller. It may be used for: • application testing in simulation mode, • data exchange between Asix.Evo applications by means of process variables. |
NordicRF |
NordicID protocol |
Protocol to exchange data with Nordic ID RF 601 bar code reader of NordicID. |
OMRON |
HOSTLINK |
Serial bus protocol for SYSMAC series PLCs. |
OmronTcpip |
FINS |
Protocol for data exchange with Omron controllers supporting the FINS/UDP and FINS/TCP protocols. |
OPC |
OPC KLIENT |
OPC (OLE for Process Control) protocol, communication with any PLC using its OPC server, according to OPC 2.04 specification. |
OPCUA |
OPC UA CLIENT |
OPC UA protocol, communication with any PLC according to OPC UA specification. |
OpcLogger |
|
Used to register measurement series read from current data OPC servers. |
Pa5 |
Pa5 |
Communication protocol for data exchange between Asix.Evo and PA-5 converters of POWOGAZ S.A. Poznan. |
PD21 |
LUMBUS |
Protocol for data exchange with PD21 concentrator made by LUMEL S.A. |
Pmc4000 |
PMC-4000 |
Communication protocol for data exchange between Asix.Evo and POLON 4800 fire alarm control panel; data are transferred via serial interface RS-232. |
PPI |
PPI |
Protocol of PPI interface for SIMATIC S7 series 200 PLC's, based on PC/PPI converter. |
Protherm300 |
PROTHERM |
Protocol of Protherm 300 DIFF PLC of Process-Electronic GmbH (RS-422 serial link). |
PROTRONICPS |
PROTRONICPS |
Communication protocol for PROTRONIC PS regulators by Hartmann & Braun. |
REST |
HTTP/HTTPS |
Used to exchange data between the Asix.Evo system application and the REST server. |
S700 |
AK |
Protocol for gas analyzers by MAIHAK. |
S7Opt |
|
Used to exchange data with the SIMATIC S7-1500 and S7-1200 series controllers (from version 4.0), constituting a completely new generation of Siemens controllers. |
S7_TCPIP |
S7_Ethernet |
Used for data exchange with SIMATIC S7 PLC’s through Ethernet connection with use of standard computer network card; the product does not require the installation of SIEMENS SIMATIC NET software on Asix.Evo system PC as well as the adaptation of PLC software for data exchange purposes. |
SAPIS7 |
MPI (CP5611/SOFTNET) |
Protocol of MPI network for SIMATIC S7 PLC's , based on CP5611/SOFTNET. |
SAPIS7 |
PROFIBUS |
S7 protocol of PROFIBUS network based on CP5412 (A2) or CP5613. |
S-BUS |
S-Bus |
Protocol of programmer unit interface and S-Bus network for SAIA Burgess Electronics PLCs. |
SbusTcpip |
Ethernet S-Bus |
Protocol used for data exchange between Asix.Evo system and PLCs of PCD SAIA-Burgess family by means of TCP/IP. |
Simulator |
|
Used to generate test trends. The trends generated can be based on previously created csv files, or calculated by the driver as a random trends and a sinusoidal trend. |
SINECH1 |
SINEC H1 |
Protocol of Ethernet industry network for SIMATIC S5 PLC's, SEND/RECEIVE interface, based on CP1413. |
SINECL2 |
SINEC L2 |
Protocol of PROFIBUS network with SEND/RECEIVE (FDL) interface for SIMATIC S5. |
Si400 |
SINTONY SI |
Communication protocol for alarm exchanges with Sintony SI 400 of SIEMENS. |
SNG |
SNG-Synergia/IP |
Protocol for data exchange between Asix.Evo and SNG systems provided by the Warsaw based Synergia Tech company, via an Ethernet link. |
SNMP |
SNMPv1 i SNMPv2c |
SNMPv1 and SNMPv2c protocols – management of various elements of telecommunication networks, such as routers, switches, computers, or telephone switchboards. The driver performs its functions by using the SNMP Management API. |
SNPX |
SNPX |
Protocol for communication with GE_FANUC 90-30 PLCs as well as GE_FANUC 90 CMM and PCM modules. |
Sp100H |
Manufacturer’s protocol |
Protocol for exchanging data between Asix.Evo and SP-100H controller of storm water center Aqua Center Industrial 100 H 14-60, produced by MARLEY Polska Sp. z o.o. The transmission is performed via serial links using RS-232 std serial port. |
SPA |
SPA |
SPA bus protocol for protection of switching stations manufactured by ABB. |
Srio |
ANSI X3.28 |
Protocol for data exchange with SRIO 500M ABB hub; communication via RS-232 interface; the transport layer based on ANSI X3.28 protocol in full-duplex mode with BCC checksum. |
SRTP |
SRTP |
SRTP protocol allowing communication over TCP/IP with VersaMax Nano/Micro PLC’s ( based on IC200SET001 converter ) and VersaMax or Series 90 PLC's over TCP/IP ( based on IC 693 CMM321). |
TALAS |
TALAS |
Serial bus protocol for TALAS pollution emission analyzers according to the TALAS 2.3 (007)22 specification. |
TwinCAT |
(with use of Beckhoff libraries) |
Data exchange between Asix.Evo and PLCs of Beckhoff Industrie Elektronik: CX1000, TwinCAT PLC ( PC based control system), BC9000, BX9000. Communication is based on Ethernet. |
TwinCATTcpip |
ADS/AMS over TCPIP (without use of Beckhoff libraries) |
Data exchange between Asix.Evo and PLCs of Beckhoff Industrie Elektronik: CX1000, TwinCAT PLC ( PC based control system), BC9000, BX9000. Communication is based on Ethernet with the use of ADS interface. |
Vantage |
Manufacturer’s protocol |
Readout of current data from weather stations of Vantage Pro family developed by Davis Instruments Corp., USA. |
Wago |
Wago |
Protocol for data exchange with Wago PLCs. Communication realized with the use of Ethernet in UDP mode based on network variable list ("Network Variables”). |
WagoUps |
Wago |
Used to communicate the Asix.Evo system with WAGO 787-87x power supplies using the RS-232 or Ethernet serial link. |
ZdarzenieZmienna |
- |
The driver is used to generate process variables of WORD types (16-bit word) on the basis of current values of alarm events in the Asix.Evo system. |
ZxD400 |
IEC 61107 |
ZxD400 driver is used for data exchange between Asix.Evo and electric energy counters of ZxD400 type, manufactured by Landys & Gyr, via RS-485 interface. |